  Datasheet File OCR Text:
  specification power factor (typ.) (typ.) (typ.) (typ.) pf>0.95/230vac pf>0.98/115vac at full load rc+/rc-:0 ~ 0.8v=power on; 4 ~ 10v=power off sink current<4~10ma remote control ac input voltage ac input current inrush current setup, rise time hold-up time leakage current dc output adj. range overload protection over voltage protection over temperature protection power good / fail signal 90~264 vac, 47~440hz / 127~370vdc. maximum input current 3.5a at 115vac, 60hz or 1.6a at 230vac, 60hz with 100% output load. inrush current is less than 25a at 115vac or less than 40a at 230vac under cold start conditions. limiting provided by internal thermistors. 1000ms, 20ms / 230vac at full load 3000ms, 20ms / 115vac at full load 16ms / 230vac at full load 16ms / 115vac at full load leakage current is less than 180 a at 264vac for earth leakage current leakage current is less than 100 a at 264vac for patient leakage current dc output voltage (or ch1 of multiple output models) can be adjusted between -5%~+10% rated output voltage by potential meter. fully protected against short circuit and output overload. the hiccup type protection will be activated at 120~160% rated load and recovers automatically after fault condition is removed. provided on output channel 1 only at 115%~135% rated output voltage. output will be shut down when this protection is activated. when the temperature of tsw1 which detect on heat sink of power transistor reaches 95 this protection is activated. then output will be shut down and recovers automatically after temperature goes down. * MPS-200-3.3 does not have this function. ttl logic high for power good and ttl low for power fail. when the output voltage reaches 90% of rated value, a +5v ttl signal will be sent out with a 10~500ms delay; at least 1ms before the output voltage goes below 90% of the rated value, the ttl signal will be turned off. compliance level en55011, class b en55022, class b en61000-3-2 en61000-3-3 compliance level en61000-4-2, en61000-4-2, en61000-4-3, en61000-4-4, en61000-4-5, en61000-4-6, en61000-4-8, en61000-4-11, env50204, level 3, 8kv level 2, 4kv level 2, 3v/m level 3, 10v/m level 2, 1kv/5khz level 3, 2kv/5khz level 4, 2kv/line-line 4kv/line-earth level 2, 3vrms/m level 3, 10vrms/m level 2, 3a/m level 3, 10a/m compliance level 2, 3v/m, 900mhz level 3, 10a/m, 900mhz 1~4 output medical type 2 0 0 w m e d i c a l s e r i e s universal ac input / full range low leakage current <180 a protections: short circuit / overload / over voltage / over temperature free air convection for 140w and forced air convection for 200w ul60601-1 medical safety approved with power good and fail signal output built-in remote on-off control fixed switching frequency at 100khz 3 years warranty built-in remote sense function features temp. coefficient vibration safety standards : withstand voltage isolation resistance emi compliance ems compliance mtbf dimension (l*w*h) packing working temp. working humidity storage temp., humidity whole series can operate from -20~70 . please refer to the derating curves. 20~90% rh non-condensing. -40~+85 , 10~90% rh 2g of acceleration, vibrating frequency adjust from 10hz ~500hz withi n a 10-minute cycle. 6 testing cycles (60 minutes) each along x, y, z axes. medical ul60601-1, tuv en60601-1 commercial : also design refer to ul60950-1, tuv en60950-1 4000vac between input and output 1500vac between input and f.g. 1500vac between output and f.g. emi specifications ems specification esd air esd contact rf field susceptibility eft(electrical fast transient)/burst lightning/surge conducted rf susceptibility magnetic field immunity voltage dip, interruption digital phone carrier immunity 262,100 hours min. at full load and 25 of ambient temperature, calculated per mil-hdbk-217f. 177.8x107.2x35.5mm or 7"x4.22"x1.4" 0.66kg; 24pcs/16.8kg/0.99cuft , approved 0.04%/ on all outputs at full load between 0~50 of ambient temperature. >100m ohms for i/p-o/p, i/p-fg, o/p-fg by using 500vdc test voltage. conducted & radiation harmonic distortion voltage flicker iec60601-1 en60601-1iec60601-1 file name:200w medical-spec 2010-10-18
1~4 output medical type 2 0 0 w m e d i c a l s e r i e s file name:200w medical-spec 2010-10-18 notes : 1. all parameters not specially mentioned are measured at 230vac input, r ated load and 25 of ambient temperature. 2. ripple & noise are measured at 20mhz of bandwidth by using a 12" twisted pair- wire terminated with a 0.1 f & 47 f parallel capacitor. 3. tolerance : includes set up tolerance, line regulation and load regula tion. 4. 33% duty cycle maximum within every 30 seconds. average output power sho uld not exceed the rated power. 5. the power supply is considered a component which will be installed into a fi nal equipment. the final equipment must be re-confirmed that it still mee ts emc directives. 6 . derating may be needed under low input voltages. please check the deratin g curve for more details. for guidance on how to perform these emc tests, please refer to ?emi testing of c omponent power supplies.? (as available on http://www.meanwell.com) output chart model output rated output current peak load with fan convection minimum ripple & noise voltage line load efficiency voltage current ( ) note 4 (25cfm) (max.) (typ.) load (max.) tolerance regulation regulation MPS-200-3.3 3.3v 0a 40a 28a 40a 48a 80mvp-p 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 77% 81% 84% 85% 86% 87% 82% 80% 80% 80% 78% 78% 79% 81% 81% 83% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 5.0% 5.0% 5.0% 5.0% 5.0% 5.0% 5.0% 5.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 4.0% +4,-6% 0.5% 0.5% 0.5% 1.0% 0.5% 0.5% 0.5% 0.5% 0.5% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 1.0% 1.0% 2.0% 2.0% 2.0% 2.0% 1.0% 1.0% 2.0% 2.0% 2.0% 2.0% 2.0% 2.0% 5.0% 5.0% 2.0% 2.0% 2.0% 8.0% 8.0% 8.0% 8.0% 8.0% 5.0% 5.0% 5.0% 5.0% 5.0% 6.0% 8.0% 8.0% 5.0% 5.0% 5.0% 5.0% 5.0% 2.0% +8,-5% 6.5% 80mvp-p 100mvp-p 100mvp-p 150mvp-p 200mvp-p 80mvp-p 80mvp-p 80mvp-p 80mvp-p 80mvp-p 80mvp-p 80mvp-p 180mvp-p 80mvp-p 80mvp-p 120mvp-p 120mvp-p 150mvp-p 120mvp-p 150mvp-p 180mvp-p 180mvp-p 80mvp-p 80mvp-p 80mvp-p 80mvp-p 80mvp-p 80mvp-p 80mvp-p 80mvp-p 80mvp-p 80mvp-p 80mvp-p 80mvp-p 80mvp-p 120mvp-p 180mvp-p 5v 0a 40a 28a 40a 48a 0a 16.7a 11.7a 16.7a 20a 0a 13.4a 9.4a 13.4a 16a 0a 8.4a 5.9a 8.4a 10a 0a 4a 4a 4a 4a 3a 3a 3a 3a 4a 0.8a 0.6a 0.5a 0.7a 0.5a 0.3a 0.3a 0.3a 0a 0a 0a 0a 0a 0a 0a 0a 0a 0a 0a 0a 4a 0.8a 0.4a 4.2a 20a 20a 20a 20a 15a 15a 15a 15a 20a 7.5a 6a 4.7a 7a 5a 3a 2.7a 3a 2a 2a 2a 2a 2a 2a 2a 2a 2a 2a 2a 2a 20a 8a 4a 3a 15a 15a 15a 15a 12a 12a 12a 12a 15a 5a 4.4a 3.3a 5.3a 4a 2.3a 2.1a 2.2a 1a 1a 1a 1a 1a 1a 1a 1a 1a 1a 1a 1a 15a 5.4a 2.7a 4.2a 20a 20a 20a 20a 15a 15a 15a 15a 20a 7.5a 6a 4.7a 7a 5a 3a 2.7a 3a 2a 2a 2a 2a 2a 2a 2a 2a 2a 2a 2a 2a 20a 8a 4a 5a 24a 24a 24a 24a 18a 18a 18a 18a 24a 9a 7.2a 5.6a 8.4a 6a 3.6a 3.3a 3.6a 2.4a 2.4a 2.4a 2.4a 2.4a 2.4a 2.4a 2.4a 2.4a 2.4a 2.4a 2.4a 24a 9.6a 4.8a 12v 15v 24v 48v 5v 5v 5v 5v 5v 5v 5v 5v 5v 12v 12v 15v 12v 15v 24v 24v 24v -5v -12v -15v -5v -5v 12v 15v -12v -15v -12v -15v 12v 5v 12v 24v MPS-200-5 MPS-200-12 MPS-200-15 MPS-200-24 MPS-200-48 mpd-200a mpt-200a mpt-200b mpt-200c mpq-200b mpq-200c mpq-200d mpq-200f mpt-200d mpd-200b with 25cfm fan (note 3) (note 2)
2 1 fg cn1 3 25cfm min. 15cm fan cn2 9 10 7 84 2 1 3 5 6 11 12 14 13 15 16 18 17 19 20 (horizontal) 3[0.118"] max. unit:mm mechanical specification(MPS-200) 1~4 output medical type 2 0 0 w m e d i c a l s e r i e s file name:200w medical-spec 2010-10-18 led svr1 cn4 165.1[6.5"] 6.35[0.25"] 177.8[7"] 107.2[4.22"] 95.25[3.75"] 6.1[0.24"] 35.5[1.4"] 4- 3.96[0.156"] 3 1 4 6 5 2 dc output connector (cn4) : or equivalent js-2008-03*2 pin no. 12 3 4 5 6 assignment pg rs- gnd rc+ rs+ rc- mating housing js-2007-03*2 or equivalent terminal js-2007-t or equivalent ac input connector (cn1) : jst b3p-vh or equivalent pin no. 12 3 assignment ac/n no pin ac/l mating housing jst vhr jst svh-21t-p1.1 or equivalent or equivalent terminal dc output connector (cn2) : molex or equivalent 5566-20 pin no. 1~5,11~15 6~10,16~20 assignment dc output -v dc output +v mating housing molex 5557 or equivalent terminal molex 5556 or equivalent derating curve (MPS-200) static characteristics (MPS-200) load (%) 10 20 30 40 50 60 70 20 40 60 80 100 -20 0 25cfm forced air cooling convection cooling ambient temperature ( ) 90 100 115 140 160 180 200 220 240 264 100 90 80 70 60 50 40 input voltage (v) 60hz load(%)
dc output connector (cn4) : js-2008-03*2 or equivalent pin no. 12 3 4 5 6 assignment pg rs- gnd rc+ rs+ rc- mating housing js-2007-03*2 or equivalent terminal js-2007-t or equivalent ac input connector (cn1) : jst b3p-vh or equivalent dc output connector (cn2,3) : jst b8p-vh*2 or equivalent pin no. pin no. 1,2,3,4 5~11 12,13 14 15 16 12 3 assignment assignment v1 com v2 v3 no pin v4 ac/n no pin ac/l mating housing mating housing jst vhr jst vhr jst svh-21t-p1.1 jst svh-21t-p1.1 or equivalent or equivalent or equivalent or equivalent terminal terminal 90 100 115 140 160 180 200 220 240 264 100 90 80 70 60 50 40 input voltage (v) 60hz load(%) load (%) 10 20 30 40 50 60 70 20 40 60 80 100 -20 0 25cfm forced air cooling convection cooling ambient temperature ( ) mpt/q-200 mpd-200 mpt/q-200 mpd-200 6.1[0.24"] 6.35[0.25"] (horizontal) 3[0.118"] max. derating curve (mpd/t/q-200) static characteristics (mpd,t,q -200) 1~4 output medical type 2 0 0 w m e d i c a l s e r i e s file name:200w medical-spec 2010-10-18 mechanical specification(mpd/t/q-200) led svr1 3 1 cn4 165.1[6.5"] 177.8[7"] 107.2[4.22"] 95.25[3.75"] 35.5[1.4"] 4- 3.96[0.156"] 46 5 2 2 1 fg cn1 3 16 cn3 cn2 1 25cfm min. 15cm fan